Info@anytek.ae
+971505194427

Industrial Computer
Tomography

  • High accuracy
  • Fast testing
  • Smart software
  • Intelligent price

Bright S Industrial CT Scanning Machine

Industrial CT scanning machine is widely used in automobile, materials, railway, aerospace, aviation, war industry, national defense and other industries, for space launch vehicle and the successful launch of the spacecraft and space vehicles, the development of aircraft engine, the large weapon system test and test, analysis of geological structure, accelerated the railway vehicle overloading safety, oil reserves prediction, mechanical products, such as quality evaluation provides important technical means.

X-Ray Emitter:
Voltage (Max)90KV/100kV/130kV/150kV
Current (Max)200μA/200μA/300μA/500μA
Power, Target (MAX)8W/20W/39W/75W
Focus Size5μm/50μm
Image Output Device:
Flat Panel Detector(Active Area):
116x 146 mm,
250 x 300 mm,
300 x 300 mm,
430 x 430 mm,
Resolution 49.5μm
Manipulator:
Loading Table Size 400mm×400mm
XYZ Stroke 400mm×400mm×200mm
Table Rotation 360°
Max. Sample Weight Max 15kg (option : 30kg)
Power Supply 220 VAC Single phase 50/60Hz
X-Ray Leakage Dose <1μSv/hour
Dimension (W×D × H ) 2000mm×1670mm×1800mm
(With monitor:2700mm×1950mm×1950mm)
Equipment Weight 2,000kg

Bright M Industrial CT Scanning Machine

X-Ray Emitter:
Voltage (Max) 160kV/240kV/300kV
Current (Max) 0.5mA (TOMXT) / 5mA (ROMXT)
Power, Target (MAX) 350W
Focus Size 4μm
Image Output Device:
Flat Panel Detector(Active Area):
150x 150 mm,
250 x 300 mm,
300 x 300 mm,
430 x 430 mm,
Resolution 49.5μm / 99μm / 145μm
Manipulator:
Loading Table Size 300mm
XYZ Stroke 300mm x 350mm x 600mm
Table Rotation360°
Max. Sample Weight Max 15kg (option : 30kg)
Power Supply 220 VAC Single phase 50/60Hz
X-Ray Leakage Dose <1μSv/hour
Dimension (W×D × H ) 2400mm x 1950mm x 1910mm
Equipment Weight 3,000kg

High power Industrial CT Inspection System

1.Standard Scan Range: 350mm.
2.Small Focus Spatial Resolution: better than 2.5LP/mm.
3.System Density Resolution: <1%.
4.CT Spatial Resolution: 2.5Lp/mm@10%, modulation (3 min RO mode, using small focus & 450mm visual field FOV)
5.CT Size Accuracy:
Accuracy: ±100μm;
Repeatability accuracy: ±20μm;
Scanning condition: RO mode 5 min scanning, 450kV, 3.33mA, slice thickness: 2mm, visual field: 300mm;
Measured object: subject is aluminum standard measuring block.
6.CT Scan Time: 6min, 720 projections, 0.5s integral time.
7.Slice Thickness Collimator (rear collimator): the software is continuously adjustable.
8.CT Image Display Matrix: the software is optional, 256 x 256 to 4096 x 4096 arbitrary

settings, 16bits (65,535 grayscale)

Environmental conditions
Operating Temperature: 10 ~ 35℃.
Storage Temperature: -40 ~ 47℃.
Ambient Humidity: 5% ~ 95% (no condensation).
Elevation: 0 ~ 3,000 meters.
5.Should have independent grounding line, with resistance value not exceeding 3 ohms and length not more than 10 meters.

The single-phase capacity shall not be less than 10 KVA; the grid fluctuationshall not exceed 10% of the rated voltage.
Our Contacts
+971 50 519 44 27
info@anytek.ae
UAE
Dubai
Al Muteena BC RES 1072 OFFICE 4C-06
Trade license:22780
Contact us
WhatsApp
Mail
Phone
Made on
Tilda